Large Measurement Volume | Expanded Field of View
The ADAM™ MC Plus measures a larger sample volume and captures a greater number of frames in each channel [NanoEnTek]. Due to this capability, the ADAM™ MC Plus delivers superior reproducibility and accuracy compared to other cell counters available on the market [NanoEnTek].
Cell Size and Aggregation Measurement
The ADAM™ MC Plus not only counts total, viable, and non-viable cells, but also determines cell viability [NanoEnTek]. Additionally, the instrument analyzes cell size and the aggregation coefficient (the degree of cell clumping into clusters) [NanoEnTek].
Accurate Results
Correlation of total peripheral blood mononuclear cell (PBMC) counts between flow cytometry, manual counting, and the ADAM™ MC Plus and CellT Plus instruments.
Linearity and reproducibility
Peripheral blood mononuclear cell (PBMC) samples at low, medium, and high concentrations were analyzed across three different ADAM™ MC Plus and CellT Plus instruments.
Applicability to Various Cell Types
The ADAM™ MC Plus is designed for high-precision counting of a wide variety of cell types, making it an ideal solution for applications in cell biology, biomedical research, drug discovery, and other fields.
A high-concentration suspension of peripheral blood mononuclear cells (PBMCs) at 1.8 x 10⁷ cells/mL was serially diluted, and the dilution series was then analyzed using the ADAM™ MC Plus and CellT Plus instruments.
The results demonstrate excellent dilution linearity and data reproducibility.
*
" Minimum sample volume: Only 15 µL required.
- Single solution:
- The sample is mixed with a single staining solution (AO/DAPI).
- 4 tests per slide: Ability to perform four analyses on a single microscope slide (counting chip).
- Comprehensive analysis: Total cell counting and cell viability determination.
- High speed: 40 seconds per slide (in fast mode).
- Aggregation percentage: Calculation of the clumped (aggregated) cell ratio in the sample.
- Low coefficient of variation (CV): High reproducibility of results.
One-Step AO/DAPI Fluorescent StainingThe ADAM™ MC Plus is an automated fluorescent cell counter that utilizes Acridine Orange (AO) and DAPI (4′,6-diamidino-2-phenylindole) to stain total and dead-only cells, respectively. The AO/DAPI dyes exclusively stain nucleated cells, effectively eliminating interferences such as cell debris or red blood cells (RBCs) in samples with complex backgrounds. This ensures high counting accuracy and reliable viability analysis.