DFC-820SP Semi-Automated Dissolution Testing System

The DFC offline systems include a fraction collector or an autosampler that collects the sampled dissolution media. The DFC-820SP semi-automated system consists of a PTWS 820D dissolution bath with a staggered stirrer start function and an integrated individual vessel centering system, a complete set of PTFE (Teflon) tubing including in-situ sampling probes or an EPE-820 automated sampling system, a PT-SP8 syringe pump, and a PTFC-2/8SP fraction collector.
In this configuration, the sampling probes are either permanently immersed in the medium (in-situ) or withdrawn after sampling (EPE-820 system). Both methods are widely used in practice.


Semi-Automated Dissolution Testing
In this context, "semi-automated" means the automatic withdrawal of samples from the dissolution testing instrument at pre-programmed times. Automating this single step significantly simplifies the testing process. Once all tablets are dropped into the medium, the test proceeds automatically, and samples are concurrently withdrawn from each connected vessel.
The sample is delivered to the connected fraction collector via a peristaltic or PT-SP syringe pump. These systems do not require external control software (the WinDiss ARGUS software package may be used optionally).
Sampling information is entered directly on the connected PTWS 120D/S dissolution testing instrument. All Pharma Test tablet dissolution instruments can be retrofitted with a pump and a PTFC-2/8 fraction collector or a DSR-M sampling robot.
Automated Sampling
The concept of automation in dissolution testing varies greatly from user to user. The most labor-intensive step is collecting samples at specific time intervals established in the company’s Standard Operating Procedure (SOP).
This involves withdrawing 6 samples in accordance with USP/EP and most other pharmacopeia requirements. Often, a fast or parallel start is required to ensure high accuracy in adhering to the sampling time frames.
At this stage, the operator must also decide whether to replace the withdrawn media volume in the vessels or keep an accurate record of the volumes removed from each vessel to calculate the true concentration for subsequent samples.
Three types of pumps are available: peristaltic, piston, or syringe pumps. The PT-SP syringe pump, as well as the valveless CAT piston pump, offer first-class accuracy regarding sample volume and media replacement back into the system.
Although the quality of modern peristaltic pumps has significantly improved, it should be emphasized that they still operate using flexible tubing. This tubing must be checked before each test run to ensure that the flow rate is identical for every channel and that the tubes themselves are in good condition. A helpful tip to extend tubing life: always release the pressure rollers if the system is left idle overnight or for an extended period.
PT-SP Multi-Syringe Pumps
The PT-SP multi-syringe pump is designed specifically for parallel sampling and media dispensing from a dissolution bath into the open vials of a fraction collector. It is equipped with a maximum of 8 interchangeable, high-precision 10 ml glass syringes. Each syringe is connected to a 3-way pinch valve to control the media flow. The syringes are driven simultaneously by a stepper motor. All syringes are rigidly coupled to a single, robust drive bar.


Peristaltic Pumps
The Ismatec® IPC 8, IPC 16, and IPC 24 pump series offer a cost-effective solution for long-term use. Thanks to the reverse flow function and the use of the PTFC-2/8 fraction collector, DFC systems provide the necessary control for sample transfer when using this type of pump in standard offline systems.
Valveless CAT Piston Pumps
CAT multi-piston pump units offer a more precise solution for sample collection and transfer. Accurate volumes can be transferred from the vessels into a fraction collector such as the PTFC-2/8. Thus, if media replacement is not utilized, the withdrawn sample volume can be precisely recorded for subsequent concentration calculations.
This system provides a more reliable sampling method for open-loop (non-closed loop) or offline systems, where in the case of peristaltic pumps, the volume is calculated based on an approximate flow rate over a fixed period of time.
The system is independent of tubing quality and serves as an excellent alternative in cases where active substances might be adsorbed by the tubing materials (e.g., Tygon or silicone). The CAT pump is available in configurations with 6, 8, 12, and 24 individual heads, including options for automatic media replacement.
Operating Principle
Once the samples (tablets) are loaded, the system starts operating in automatic mode. Sampling times are programmed via the touchscreen of the PTWS 820D dissolution bath and saved as a specific method for subsequent tests.
After the test begins, the bath sends a command to the PTFC-2/8 fraction collector, and from there to the connected pump to initiate the sampling cycle. The EPE-820 system lowers the sampling lines with filter tips into the media to the specified depth.
The pump starts to prime and pre-flush the tubing. Once all lines are filled, samples are collected into vials on the PTFC-2/8 collector rack. Depending on the configuration, media volume replacement can be performed after dispensing, after which the EPE-820 withdraws the lines from the vessels.
At the end of the cycle, all tubes are purged, and the system waits for the next sampling time. All vials remain closed (by the collector cover) during the test; the vial rack is easily removable. Special racks for HPLC vials are also available.
This implies collecting 6 samples according to USP/EP and most other pharmacopeias. Often, a fast or parallel start is required to ensure strict adherence to time intervals.
At this stage, the operator must consider either replacing the withdrawn volume in the vessels or keeping an accurate log of the volumes taken from each vessel to calculate the true concentration in subsequent samples.
Three types of pumps are available: peristaltic, piston, or syringe pumps. The PT-SP syringe pump, as well as the valveless CAT piston pump, provide the highest precision for both volume sampling and media return to the system.
Features
  • Automatic temperature verification and logging: Records temperature data at each sampling event.
  • Full regulatory compliance: Fully compliant with USP <711/724> and EP <2.9.3/4> standards.
  • 8 stirred positions: Provides configuration for full-scale testing.
  • Complete system integration: The system consists of a PTWS 820D dissolution bath, a PTFC-2/8SP fraction collector, and a PT-SP8 syringe pump. Alternatively, Ismatec peristaltic pumps or CAT piston pumps can be used.
  • Automated sampling at scheduled times: Executed via movable probes (requires the EPE-820 system).
  • Media temperature monitoring during sampling: Enables real-time logging (requires the ITM-820 system).
  • Parallel tablet drop: Supports synchronized initiation (requires the TM-820 or TMA-820 device).
  • Test report printing: Provides hard-copy documentation (requires the PT-RP80 printer).
  • Automatic media replacement: Maintains consistent vessel volumes.
Advantages
  • Automates the most labor-intensive step: Streamlines sample collection during the dissolution test.
  • Eliminates human error: Identical sampling times and standardized solvent transport ensure high reproducibility.
  • Excellent reproducibility: Delivers consistent sample volumes and precise collection timing.
  • Unattended operation: Allows for walk-away testing after the dissolution process is initiated.
  • Single-source responsibility: Pharma Test takes full responsibility for the performance of the entire assembled system.


Technical specifications
Options
Included in the Standard Scope of Delivery
  • TM-820 manual tablet drop magazine: For synchronized manual sample introduction.
  • EPE-820 automated sampling system: Features motorized probe immersion.
  • Complete PTFE (Teflon) tubing set: Configured for offline sampling workflows.
  • PTFC-2/8SP fraction collector: Dedicated unit for sample collection.
  • PT-SP8 syringe pump: High-precision multi-syringe dosing unit.
  • Complete set of stainless steel paddle stirring tools: Aligned with pharmacopeial standards.
  • Complete set of 1000 ml borosilicate glass vessels: Heat-resistant and durable.
  • Set of depth adjustment calibration balls: Ensures correct tool positioning.
  • One bottle of ALGEX water preservative: Prevents algae growth in the water bath.
  • Comprehensive documentation package, including:
  • User Manual
  • Instrument Design Qualification and Quality Control Certificate (DQ/QC)
  • Installation Qualification documentation (IQ)
  • Operational Qualification documentation (OQ)
  • Instrument Logbook
  • Conformity Certificates for vessels and stirring tools
Options (Optional Equipment)
  • Tubing cleaning system with magnetic holders: Simplifies flushing and maintenance lines.
  • Amber glass vessels: Provides UV protection for light-sensitive samples.
  • ITM-820 individual media temperature monitoring system: For real-time temperature logging in each vessel.
  • TMA-820 motorized automatic tablet drop magazine: Enables fully automated test initiation.
  • PT-RP80 serial report printer: For direct, secure data documentation.
  • Automated media replacement configurations: Additional connected PT-SP syringe pump for media replacement, or an E-VEN pinch valve system on the PTFC-2/8 fraction collector coupled with a 16- or 24-channel peristaltic pump.
  • Customized collector racks: Available for HPLC vials or alternative tube/vial dimensions.
  • Full range of MonoShaft™ stirring tools: Comprehensive selection of baskets, paddles, and cylinders.
  • Filter tips with various pore sizes: For customized pre-filtration during sampling.
  • Full set of certified validation tools: For routine calibration and physical qualification.
Video
Brochure
LITERATURE
Made on