Why Measure Powder Flow Properties?It is estimated that more than 50% of materials used in industry have been in powder form at some stage. These powders must be transported, injected, conveyed, and passed through various processing stages before reaching their final form. This final product may be a tablet, a suspension, or the powder formulation itself. The need to measure, control, and test for consistent powder flowability is well established across many industries.Powder flow properties are important for:- Reducing raw material costs: rejecting poor batches before processing begins.
- Maintaining an optimal formulation for a specific manufacturing process.
- Reducing production costs.
- Maintaining the quality and stability of the final product.
- Optimizing product storage, packaging, loading, and transportation.
- Controlling raw material quality from different suppliers or from a single supplier over time.
- Developing new processes for forming powders into finished products.
- Checking the effects of humidity when operating in open systems across different climates.
- Researching and controlling the quality of dry blends.
In processes that depend on the uniformity of a powder or blend, proper flowability is of paramount importance. Powder blends must be dosed, mixed, and transported. Moving them even over short distances can easily lead to segregation (separation). During this process, fine particles settle, altering the particle size distribution and flow properties.Tableting ExampleBlends for tablet presses must flow consistently from batch to batch. Active ingredients typically do not flow naturally. They are sticky (cohesive) and prone to agglomeration (clumping). Reducing active ingredient dosages requires their consistent distribution within an inactive medium (carrier) in mixers before feeding into a tablet press.
Inactive ingredients (MCC — microcrystalline cellulose, starch, lactose) are natural products. Their particle size, tendency to clump, and surface area depend on the raw material source. The effect of additives such as silicon dioxide (e.g., Aerosil 300), which improve the flowability of such complex powders, must also be taken into account. Testing each component and the finished blend at the right stage saves time, money, and resources.
Operating Principle of the PTG-S5 (Intended Use)
The PTG-S5 is widely used to compare powder batches supplied by the same manufacturer over time or similar materials from different suppliers. Flow properties can be easily and quickly determined and used as a quality control (QC) tool to verify batch-to-batch reproducibility. This is critical for uninterrupted production, particularly when powders are prone to clumping (agglomeration) and sticking (cohesion) during storage.
Design and Compliance with Standards
The instrument design fully complies with the requirements of ISO 4324 (12/83), EP <2.9.36> (European Pharmacopoeia), and USP <1174> (United States Pharmacopeia). The test sample is poured into a conical funnel, which can be fitted with various discharge nozzles. The product receiving dish is placed on an integrated Sartorius analytical weighing cell. For poorly flowing powders, the PTG-ER electric stirrer can be used. Most pharmaceutical materials contain so many fine fractions (dust-like particles) that they cannot initiate flow on their own without external agitation.
Test Procedure
Next, start the test. Depending on the powder type, the PTG-ER stirrer may be used. Once the test starts, the funnel opens and two IR sensors detect the powder flow. This triggers a timer to measure the flow time and plot the flow curve. The product itself collects on a 100 mm diameter dish and forms a cone. As soon as the powder flow stops, the funnel closes, and a movable measuring arm carrying two infrared sensors begins measuring the cone height all the way to its apex. Since the surface of the receiving dish is completely covered, the instrument can calculate and display the cone angle (angle of repose).
The test must be repeated five times (in accordance with ISO 4324), with the deviation of results not exceeding 5%. The test results are displayed on the color touchscreen of the PTG-S5. The test report and the powder flow curve are printed out together with descriptive product information. The report can be printed either on the built-in thermal printer or on any Windows-compatible printer connected directly to the instrument via USB or over a network.
Measurement
To measure flowability in accordance with the requirements of the European Pharmacopoeia (EP) <2.9.16> and the United States Pharmacopeia (USP) <1174>, the test stops automatically as soon as 100 g of sample is collected in the plastic beaker. In addition to the flowability factor (100 g/time), a powder flow curve can be printed out. The standard scope of delivery includes all accessories for measuring flow time, cone angle, and flowability in compliance with current EP/USP standards. Various discharge nozzles with diameters ranging from 4 to 10 mm can be used for product testing. A stirrer can be used to force non-flowing products through the selected nozzle.
Furthermore, a graph illustrating the flow behavior of the tested sample can be plotted on the built-in printer. The cone angle can also be measured using a stainless steel conical funnel, as described in the current EP/USP monograph, along with interchangeable nozzles of 10, 15, and 25 mm in diameter. If smaller-diameter nozzles are required, an adapter ring is provided to accommodate discharge nozzles from 4 to 10 mm.
Features- Full compliance with USP <1174>, EP <2.9.36>, EP <2.9.16>, and ISO 4324 (12/83) standards
- Measurement of flow time, cone angle (angle of repose), flowability, cone density, and cone volume
- PTG-ER stirrer included
- Built-in analytical weighing module (load cell)
- Integrated protective hood for dust protection
- Built-in printer
Advantages- Reduction of manufacturing and processing costs
- Improved batch-to-batch product quality consistency
- Strict control of raw powder components, particularly those of natural origin
- Comparison of powder products from different suppliers
- Simple incoming quality control method for bulk components
- Simple monitoring method for dry and wet mixing, tableting, granulation, and capsule filling processes
- Prediction of powder behavior during conveying, pneumatic lifting, and storage in silos
- Prediction of powder suitability for capsule and vial filling
- Prediction of product settling (separation), known as segregation, during transport
- Prediction of powder impact on tablet hardness and the stability of solid dosage forms
- Prediction of powder impact on tablet disintegration and friability
- Integrated transparent protective hood for dust protection