Refrigerated benchtop centrifuge

Sigma 4-5KL

The high-performance Sigma 4-5KL laboratory centrifuge is designed for high throughput and large capacity. High torque ensures exceptionally short acceleration times, significantly increasing the efficiency of laboratory processes. This centrifuge is recommended for use in clinical diagnostics and Life Sciences research.
The refrigerated version, Sigma 4-5KL, with a temperature control range from -10 °C to +40 °C, is recommended for protecting samples with particularly sensitive temperature conditions.
The Sigma 4-5KL model also features a low noise level and a wide range of accessories. Up to 50 different routine operating protocols can be saved and easily recalled in the program memory.




What makes the Sigma 2-7 benchtop centrifuge so attractive?
The Sigma 2-7 centrifuge attracts attention with its innovative features. One of its key highlights is the blue LED operation indicator, which allows operators to see from a considerable distance whether the centrifugation cycle has finished. Other unique features include 10 program memory slots (an unmatched figure in its class), as well as an optional feature to program the instrument's start and stop times. The delayed start function was specifically developed for working with blood collection tubes in clinical in vitro diagnostics (IVD).
The required blood clotting time can be preset directly on the device, helping to optimize workflows.
The benchtop centrifuge is available with a large selection of swing-out and fixed-angle rotors, as well as various buckets and adapters. A wide range of accessories accommodates tubes and bottles with volumes from 1.5 ml to 100 ml, as well as microtiter and deep-well plates.
The Sigma 2-7 model is also available in a special IVD version (for in vitro diagnostics).
Sigma 2-7 laboratory centrifuge with an open lid, frequently used for cell culture work. Sigma 2-7 laboratory centrifuge with closed and open lids, frequently used for cell culture work. Sigma 2-7 benchtop centrifuge with a closed lid, frequently used for centrifuging blood tubes.
Rotor technical parameters (1 / 2 / 3)
Swing-out rotor:
  • Max. capacity: 400 ml
  • Max. speed: 4,000 rpm
  • Max. acceleration: 2,486 × g (RCF)
Fixed-angle rotor:
  • Max. capacity: 450 ml
  • Max. speed: 4,000 rpm
  • Max. acceleration: 2,540 × g (RCF)
Product options
  • In vitro diagnostics (IVD) equipment
  • Ready-made packages (equipment kits) for clinics and cell culture laboratories
Areas of application / Users
  • Hospitals
  • Neonatal departments (infant stations)
  • Children's hospitals
  • Veterinary clinics
  • Food quality control laboratories
  • Universities and institutes
  • Pharmaceutical laboratories
  • Private medical practices
  • Cell culture laboratories
Rotors
  • Swing-out rotor 11071 + Bucket 13299
  • Capacity: 4 × 100 ml
  • Maximum speed: 4,000 rpm
  • Maximum relative centrifugal force (RCF): 2,540 × g


  • Swing-out rotor 11123 + Bucket 13223 (plate bucket / carrier)
  • Capacity: 2 × 50 mm (maximum stack height of plates per bucket)
  • Maximum speed: 4,000 rpm
  • Maximum relative centrifugal force (RCF): 2,111 × g
  • Swing-out rotor 11037 + Bucket 13035
  • Capacity: 8 × 15 ml
  • Maximum speed: 4,000 rpm
  • Maximum relative centrifugal force (RCF): 2,379 × g


  • Fixed-angle rotor 12072
  • Capacity: 20 × 15 ml
  • Maximum speed: 4,000 rpm
  • Maximum relative centrifugal force (RCF): 2,486 × g



General characteristics
broschuer Sigma

LITERATURE
Operating Manual

Made on
Tilda