Refrigerated benchtop centrifuge

Sigma 4-5KL

The high-performance Sigma 4-5KL laboratory centrifuge is designed for high throughput and large capacity. High torque ensures exceptionally short acceleration times, significantly increasing the efficiency of laboratory processes. This centrifuge is recommended for use in clinical diagnostics and Life Sciences research.
The refrigerated version, Sigma 4-5KL, with a temperature control range from -10 °C to +40 °C, is recommended for protecting samples with particularly sensitive temperature conditions.
The Sigma 4-5KL model also features a low noise level and a wide range of accessories. Up to 50 different routine operating protocols can be saved and easily recalled in the program memory.


What makes the Sigma 4-5KL refrigerated benchtop centrifuge so attractive?
The Sigma 4-5KL refrigerated centrifuge is recommended for any task where strict temperature control of the samples is required. To save electricity and reduce costs, it features an ECO mode. If the centrifuge is not used for a user-defined period of time, it automatically enters standby mode. In addition to energy efficiency, this improves the working environment in the laboratory: turning off the cooling significantly reduces the noise level. This refrigerated centrifuge takes up very little space on the workbench (has a compact footprint) and offers an excellent price-performance ratio.
The Sigma 4-5KL model is also available in an unrefrigerated version and in a special IVD version (for in vitro diagnostics).
Rotor technical parameters (1 / 2 / 3)
Swing-out rotor:
  • Max. capacity: 3,000 ml (e.g., 4 × 750 ml)
  • Max. speed: 5,700 rpm
  • Max. acceleration: 5,485 × g (RCF)
Fixed-angle rotor:
  • Max. capacity: 564 ml
  • Max. speed: 13,500 rpm
  • Max. acceleration: 20,376 × g (RCF)
Product options
  • In vitro diagnostics (IVD) equipment
  • Biosafe (hermetically sealed) swing-out and fixed-angle rotors
  • Ready-made packages (equipment kits) for clinics and cell culture laboratories
  • RS232 communication interface
Areas of application / Users
  • Hospitals
  • Food quality control laboratories
  • Universities and institutes
  • Pharmaceutical laboratories
  • Cell culture laboratories
  • Environmental laboratories
Rotors
  • Swing-out rotor 11660 + Bucket 13450
  • Capacity: 4 × 750 ml
  • Maximum speed: 4,700 rpm
  • Maximum relative centrifugal force (RCF): 4,643 × g




  • Swing-out rotor 11660 + Bucket 13460 (multi-tube bucket)
  • Capacity: 4 × 25 × 15 ml (100 × 15 ml tubes in total per run)
  • Maximum speed: 4,700 rpm
  • Maximum relative centrifugal force (RCF): 4,470 × g



  • Swing-out rotor 11650 + Bucket 13450
  • Capacity: 4 × 750 ml
  • Maximum speed: 4,700 rpm
  • Maximum relative centrifugal force (RCF): 4,643 × g



  • Swing-out rotor 11118 + Bucket 13218 (plate bucket / carrier)
  • Capacity: 2 × 93 mm (maximum stack height of plates per bucket)
  • Maximum speed: 5,700 rpm
  • Maximum relative centrifugal force (RCF): 5,485 × g




General characteristics
broschuer Sigma

LITERATURE
Operating Manual