Streamline® Class III Biological Containment Isolator

The Streamline® Class III Containment Isolator (SCI Class III) configuration operates exclusively under negative pressure. An integrated blower maintains a negative pressure ranging from -37 Pa to -125 Pa (max) in the process chamber and from -25 Pa to -75 Pa (max) in the pass-through airlock.
"To fully comply with biosafety standards, the unit must be connected to the facility's facility exhaust system to satisfy the negative pressure requirements for BSL-III level."
The system delivers a single-pass, unidirectional airflow that complies with ISO Class 5 cleanliness, guaranteeing work zone sterility throughout the entire production process. It is also equipped with dual exhaust HEPA filters featuring a Bag-In / Bag-Out (BIBO) safe-change system to prevent accidental pathogen exposure during filter maintenance.


Key Benefits:
  • The world's most certified Class III isolator, complying with all international biosafety standards.
  • Pressure leak-tested (Class 3) in accordance with ISO 10648-2.
  • ISO Class 5 air cleanliness in accordance with ISO 14644-1.
  • Fast purge time.
  • Extremely high negative pressure (up to -125 Pa) in the process chamber, enhancing operator and environmental protection.
Specifications:
  • ULPA filters (per IEST-RP-CC001.3) and HEPA (H14) filters (per EN 1822) with a typical efficiency of >99.995% for 0.1 to 0.3-micron particles provide ISO Class 3 air cleanliness in accordance with the ISO 14644-1 standard.
  • Airtight static seals complying with FDA standards.
  • Sentinel™ Gold microprocessor controller manages all functions and monitors airflow and pressure parameters in real time.
  • Durable double-wall construction. The unique Esco Dynamic Chamber™ plenum surrounds the filter seals with a negative pressure zone.
  • Safe-change glove rings allow Hypalon sleeves to be replaced with zero risk of contaminating the work zone or the environment.
Key Point: Please note that this model provides an ISO Class 3 cleanliness level, which is significantly cleaner than the standard ISO Class 5 (Grade A).


Total Exhaust
  • Ambient air is drawn through an inlet pre-filter and the main filter by the primary blowers located at the top of the isolator. This creates positive pressure in the plenum, delivering a downflow velocity of 0.40 m/s ± 20%.
  • The pre-filter extends the lifespan of the main filters by trapping large particles that could quickly clog them.
  • The downflow provides an ISO Class 5 environment and unidirectional airflow inside the isolator, protecting materials within both the main chamber and the pass-through airlock.
  • Air from the work zone and airlock is rapidly removed by blowers to maintain cleanliness. The exhaust air passes completely through HEPA filters, guaranteeing that only purified air is discharged into the environment.


Additional Information:
  • Filter type: H14 HEPA filters with an efficiency of >99.995%.
  • Window material: Polycarbonate.
  • Port diameter: 200 mm (round).
Technical specifications
Exhaust air flow rate of the building's exhaust system: